50+ Points for House Evaluation by Yourself
Look for nearby:
- Public Transportation
- Work Places
- Malls, Shopping centers, etc
Locality Analysis:
Approach Roads -
- At least 2 cars to pass by each other without a problem.
- Parking
Neighborhood -
- Class of people living nearby
- Traffic density
- Noise Level
Safety & Cleanliness -
- Safety & Security
- Hygienic enough
Site Evaluation:
Housing -
- Low rise (G + 4)
- City-centric location
- Maximum 6-8 units per floor
Amenities -
- Lift
- Water
- Power
- Distance from public transportation
- Infrastructure
- Workplace
- Carpet area (Min. 600 Sq Ft / 70 Gaj)
- The built-up area should be around 14% more than the carpet area
- Volume of Habitation (2700 – 5400 Cu. Ft)
Site Evaluation:
Entry -
- Covered Parking
- In the parking guard room
- Lift facility
- The heat-resistant coating on the top floor (Teflon ki tivac coating)
Drawing Room (Min. 13’ x 12’ ft) -
- Space for L corner shape sofa set
- Space for T.V Unit
- Space for easy passage
- Space for center table
Bedroom (Min. 10’ x 10’ ft) -
- Inbuild wardrobes
- Space for T.V Unit
- Provision for AC (Window AC, Piping)
- Proper ventilation (Window, Balcony)
- Clear Passage
- Access to Balcony etc.
Kitchen (Min. 8’ x 5.5’ ft) -
- Attached with drawing room
- Proper ventilation
- Space for a chimney, RO, and Geyser
- Enough storage
- Space for fridge & so on.
Toilet (Min. 6.5’ x 4.5’ ft) -
- Should be 2 toilets in 2bhk & in 3bhk (1 attached with drawing area & 1 attached
with bedroom)
- Washbasin with mirror -> Seat <-> Shower area -> window exhaust
- Brand matters
- Space for accessories
- Towel hanger
Balcony (Min. 3.5’ ft wide) -
- 1 should attach with room in 2bhk
- 2 should attach with room in 3bhk
- Washing Machine water point
- Electricity point
Storage & Interiors -
- Almirah & its size
- Fall Ceiling
- Jumar
- Fan
- Fancy light
- Pain shades
- Wallpaper
Steel used -
- 304 Grade stainless steel (304 SS)
Tiles -
- DCVT (Double Charged Vitrified Tiles)
Door -
- Main door: 3’ – 3.5’ ft wide
- Bathroom door: 2.5’ ft wide
- Height of door: Min. 7’ – 7.5’ ft
Common Utility -
- Lift – Power backup
- Power backup
- Covered car parking
- 2-wheeler parking
- Separate water tank
- Water connection (How many summer Savill or underground water tanks)
- Roof rights (Either builder or top floor)
"This blog post is a testament to the author's expertise in building inspections and installation. I found it incredibly insightful and well-explained." Are you a home buyer or investor looking for a New House Building Inspection Brisbane? Please talk to Total Building Inspections QLD.